Quantcast
Channel: EdgeRouter topics
Viewing all articles
Browse latest Browse all 20028

Hardcode speed/duplex on ERPro8

$
0
0

Sorry if this has been covered somewhere already.

 

I have a VZON connection with a copper hand-off - Verizon insists that the port on my equipment be set to 100/full

when set to autoneg the connection is negotiated as 100/half and I get very poor performance on the circuit.

it is a 50mbps circuit and I cannot get more than  2-3 mbps while doing iperf testing.

 

I tried connecting a laptop directly to the hand-off for testing (set nic to 100/full as directed by carrier)

testing had satisfactory results using iperf.

 

when I set the erpro 8 to 100/full the ethernet interface did not link.

 

using the commands

 

set interfaces ethernet eth1 speed 100

set interfaces ethernet eth1 duplex full

commit

 

 

Version: v1.3.0
Build ID: 4605996
Build on: 10/14/13 18:11
Copyright: 2012-2013 Ubiquiti Networks, Inc.
HW model: EdgeRouter Pro 8-Port

 

 

Thank you,